Advertisement

Quick Links

FLEX MINI
User Manual
Article No: RGB-RD-UM-FLEX MINI E002
Version: V1.2

Advertisement

Table of Contents
loading

Summary of Contents for RGBlink FLEXMINI

  • Page 1 FLEX MINI User Manual Article No: RGB-RD-UM-FLEX MINI E002 Version: V1.2...
  • Page 2: Table Of Contents

    Chapter 5 Appendix ..............................24 5.1 Specification ..............................24 5.2 Dial Setting ..............................24 5.3 Terms & Definitions ............................27 5.4 Revision History .............................. 33 © Xiamen RGBlink Science & Technology Co., Ltd. | support@rgblink.com | www.rgblink.com Ph: +86 592 5771197...
  • Page 3: Declarations

    RGBlink. If the purchaser or a third party carries out modifications or repairs on goods delivered by RGBlink, or if the goods are handled incorrectly, in particular if the systems are commissioned operated incorrectly or if, after the transfer of risks, the goods are subject to influences not agreed upon in the contract, all guarantee claims of the purchaser will be rendered invalid.
  • Page 4: Operators Safety Summary

    To protect users from electric shock, ensure that the chassis connects to earth via the ground wire provided in the AC power Cord. The AC Socket-outlet should be installed near the equipment and be easily accessible. © Xiamen RGBlink Science & Technology Co., Ltd. | support@rgblink.com | www.rgblink.com Ph: +86 592 5771197...
  • Page 5 The environment in which you install your product should be clean, properly lit, free from static, and have adequate power, ventilation, and space for all components. © Xiamen RGBlink Science & Technology Co., Ltd. | support@rgblink.com | www.rgblink.com Ph: +86 592 5771197...
  • Page 6: Chapter 1 Your Product

    Save and load up to 40 presets  Control via crystal button,Web,APP and RS232  Support auto-storing when power off and auto-restoring data when booting  © Xiamen RGBlink Science & Technology Co., Ltd. | support@rgblink.com | www.rgblink.com Ph: +86 592 5771197...
  • Page 7: Technical Datasheet

    482(L)*420.5(W)*192.1(H) 482(L)*420.5(W)*370.6(H) Weight 6KG(net) 12.5KG(net) 25KG(net) Power 17W(net) 21W(net) 30W(net) Power AC 180V-240V 50/60HZ, Working -10℃ - 50℃ Temperature Store -25℃ - 55℃ Temperature © Xiamen RGBlink Science & Technology Co., Ltd. | support@rgblink.com | www.rgblink.com Ph: +86 592 5771197...
  • Page 8: Dimensions

    1.4 Dimensions FLEX 9(MINI) FLEX 18(MINI) © Xiamen RGBlink Science & Technology Co., Ltd. | support@rgblink.com | www.rgblink.com Ph: +86 592 5771197...
  • Page 9 FLEX 36(MINI) © Xiamen RGBlink Science & Technology Co., Ltd. | support@rgblink.com | www.rgblink.com Ph: +86 592 5771197...
  • Page 10: Panels

    For saving the scene or setup CONTROL ENTER Enter button DOWN Downward and short cut button for canceling to ALL outputs RECALL For recalling the saved scene © Xiamen RGBlink Science & Technology Co., Ltd. | support@rgblink.com | www.rgblink.com Ph: +86 592 5771197...
  • Page 11 HDMI output card ⑨ Output Slots Supports DVI/HDMI/VGA/CVBS/YPbPr/FIBER/HDBaseT outputs ⑩ Power Port AC 220V-240V 50/60Hz ⑪ Power Switch Power ON/OFF switch with light ⑫ © Xiamen RGBlink Science & Technology Co., Ltd. | support@rgblink.com | www.rgblink.com Ph: +86 592 5771197...
  • Page 12: Chapter 2 Use Your Product

    Accordingly to connected LAN port, enter the corresponding IP address, if using the LAN2, then enter 192.168.1.80 in the browse(Recommend with Google Chrome) as below: © Xiamen RGBlink Science & Technology Co., Ltd. | support@rgblink.com | www.rgblink.com Ph: +86 592 5771197...
  • Page 13: Switch

    Close one input to all the outputs Switch all inputs on all outputs Close all inputs to all outputs Switch to the scenes Save and Recall interface © Xiamen RGBlink Science & Technology Co., Ltd. | support@rgblink.com | www.rgblink.com Ph: +86 592 5771197...
  • Page 14 Users can have multiple video walls by the same way to create, for the 9x9 matrix switcher, the video wall configuration will be limited to 9, it means the configuration could be 3x4 video wall. © Xiamen RGBlink Science & Technology Co., Ltd. | support@rgblink.com | www.rgblink.com...
  • Page 15 To delete the video wall, users will only need to enter the video wall number in the del box and click “del’. © Xiamen RGBlink Science & Technology Co., Ltd. | support@rgblink.com | www.rgblink.com Ph: +86 592 5771197...
  • Page 16: Scene

    “Switch” and “Scenes” interface. With this renaming function, it can be easier for the users to know the sources and ends. © Xiamen RGBlink Science & Technology Co., Ltd. | support@rgblink.com | www.rgblink.com...
  • Page 17: Setup

    Users can reboot, change the IP address, set up the login user names, language and the RS232 baud rate settings here. After changed the IP address, will need to reboot the matrix switcher, then the new IP address will take effect. © Xiamen RGBlink Science & Technology Co., Ltd. | support@rgblink.com | www.rgblink.com Ph: +86 592 5771197...
  • Page 18: More

    IP addresses. As below are showing 3 matrices, users can rename each matrix and click button to do the switching or open in a new manage window. © Xiamen RGBlink Science & Technology Co., Ltd. | support@rgblink.com | www.rgblink.com...
  • Page 19: App Control

    IP addresses are: 192.168.0.80 or 192.168.1.80): Step 2: After Enter the IP address, it will need to login, the default user name and password both are the admin: © Xiamen RGBlink Science & Technology Co., Ltd. | support@rgblink.com | www.rgblink.com...
  • Page 20: Ir Remote Control

    *Please NOTE: The EDID is not functional on this IR remote control for this 9x9 Modular Matrix Switcher as it couldn’t support the EDID management. © Xiamen RGBlink Science & Technology Co., Ltd. | support@rgblink.com | www.rgblink.com Ph: +86 592 5771197...
  • Page 21: Com Control Commands

    Beep sound BeepOFF. Buzzer off Check the Input Y to outputs switching status Y=1,2,3,4..Eg. “1?.” means to check Input 1 switching status Note: © Xiamen RGBlink Science & Technology Co., Ltd. | support@rgblink.com | www.rgblink.com Ph: +86 592 5771197...
  • Page 22: Trouble Shooting And Attention

    Dial the switcher 7 to 1, then dial the switcher1,2 and choose the corresponding inputs.  Make sure the resolution less than WUXGA(1920*1200)/ 60HZ.  Make sure the display can support the output resolution.  © Xiamen RGBlink Science & Technology Co., Ltd. | support@rgblink.com | www.rgblink.com Ph: +86 592 5771197...
  • Page 23: Chapter 3 Order Code

    FLEX MINI Series Single HDMI 1.3 Output Module 790-0009-25-0 FLEX MINI Series Single 1080P DVI Output Module 790-0009-27-0 FLEX MINI Series Single 1080P 100m HDBaseT Output Module © Xiamen RGBlink Science & Technology Co., Ltd. | support@rgblink.com | www.rgblink.com Ph: +86 592 5771197...
  • Page 24: Chapter 4 Support

    Chapter 4 Support 4.1 Contact us © Xiamen RGBlink Science & Technology Co., Ltd. | support@rgblink.com | www.rgblink.com Ph: +86 592 5771197...
  • Page 25: Chapter 5 Appendix

    2. If select 3.5mm inputs audio input,dial D6=0 No definition When ON=0,digital =1 1080P/50 1080P/60 Audio and Image Version Description Display image normally © Xiamen RGBlink Science & Technology Co., Ltd. | support@rgblink.com | www.rgblink.com Ph: +86 592 5771197...
  • Page 26 3. If select mirror output,D7=0 800*600@75 4. If turn on IR,D8=0 480i60 576i50 480p60 576p50 1280*720@24 1280*720@25 1280*720@30 1280*720@50 1280*720@60 1080i50 1080i60 1080p24 1080p25 1080p30 1080p50 © Xiamen RGBlink Science & Technology Co., Ltd. | support@rgblink.com | www.rgblink.com Ph: +86 592 5771197...
  • Page 27 4096*2160/50 When ON =0,digital should be 1 1366*768/60 1024*768/60 3840*2160/30 4096*2160/30 480p/60 720p/50 1. If select RGB444,D5,D6=1 576p/50 2. If select 192081200@60,then D1,D2,D3,D4=1101 3840*2160/60 © Xiamen RGBlink Science & Technology Co., Ltd. | support@rgblink.com | www.rgblink.com Ph: +86 592 5771197...
  • Page 28: Terms & Definitions

    (U-SDI) for transmitting 4K and 8K signals using a single optical cable. The interface was standardized as the SMPTE ST 2036-4. © Xiamen RGBlink Science & Technology Co., Ltd. | support@rgblink.com | www.rgblink.com Ph: +86 592 5771197...
  • Page 29 1,000 meters (3,300 ft). ●SFP: Small form-factor pluggable , is a compact, hot-pluggable network interface module used for both telecommunication and data communications applications. © Xiamen RGBlink Science & Technology Co., Ltd. | support@rgblink.com | www.rgblink.com Ph: +86 592 5771197...
  • Page 30 Gen 2x2 (original name USB 3.2) with speed up to 5Gbps,10Gbps,20Gbps respectively. USB version and connectors figure: Type Type B Mini Mini Micro- Micro Type C USB 2.0 USB 3.0 3.1&3.2 © Xiamen RGBlink Science & Technology Co., Ltd. | support@rgblink.com | www.rgblink.com Ph: +86 592 5771197...
  • Page 31 ●RTMP: Real-Time Messaging Protocol (RTMP) was initially a proprietary protocol developed by Macromedia (now Adobe) for streaming audio, video and data over the Internet, between a Flash player and a server. © Xiamen RGBlink Science & Technology Co., Ltd. | support@rgblink.com | www.rgblink.com...
  • Page 32 ●Colour Temperature: The colour quality, expressed in degrees Kelvin (K), of a light source. The higher the colour temperature, the bluer the light. The lower the temperature, the redder the light. Benchmark colour temperature © Xiamen RGBlink Science & Technology Co., Ltd. | support@rgblink.com | www.rgblink.com...
  • Page 33 ●UHD: Standing for Ultra High Definition and comprising 4K and 8K television standards with a 16:9 ratio, UHD follows the 2K HDTV standard. A UHD 4K display has aphysical resolution of3840x2160 which is four times the area and twice © Xiamen RGBlink Science & Technology Co., Ltd. | support@rgblink.com | www.rgblink.com...
  • Page 34: Revision History

    Aster 2.Revise Key Features All information herein is Xiamen RGBlink Science & Technology Co Ltd. excepting noted. is a registered trademark of Xiamen RGBlink Science & Technology Co Ltd. While all efforts are made for accuracy at time of printing, we reserve the right to alter otherwise make change without notice.

Table of Contents