Removal of the RJ45 connector
Procedure
1. Turn the locking ring of the connector counterclockwise into the "unlocked" position.
2. Check that the two tabs are disengaged from the latches.
3. Pull the connector out of the RJ45 socket of the Sensor Module.
You have now released the DRIVE-CLiQ connection.
7.4.4.3

Handling the quick-action locking

The motors are equipped with SPEED-CONNECT connectors.
Using SPEED-CONNECT, you can also connect cables with quick-release lock to the motor
connector just the same as conventional cables with screw connectors (with full thread).
Note
We recommend cables with SPEED-CONNECT, as these are easier to handle.
SIMOTICS S-1FG1 servo geared motor
Operating Instructions, 12/2022, A5E47360747B/RS-AC
Turn the locking ring counterclockwise.
→ Both tabs are pressed away by the latches.
Connecting
7.4 System integration