6" Pump Cable Guard - Franklin Electric SSI Series Assembly Manual

Submersibles
Table of Contents

Advertisement

5. Apply Loctite® 302-43 to the set screw from the motor coupling
kit.
6.
Reinstall the screw on the shaft coupling, using a 5 mm Allen
wrench to tighten.
NOTE: If coupling O-Ring is not installed, place the O-Ring into
the coupling O-Ring groove, making sure it is placed properly.
7.
Once secured, identify the cable guard included with the corre-
sponding pump model.

6" Pump Cable Guard

1.
Orient the cable guard so the angled tab is on the motor
bracket end and the top two tabs extend past the pump's dis-
charge.
2. Install the cable guard tabs closest to the motor bracket.
3. Gently tap the side of the cable guard to drive one of the tabs
under the strap.
Do not tap the tabs.
ASSEMBLY INSTRUCTIONS
Cable Guard Assembly
9

Advertisement

Table of Contents
loading