Franklin Electric SubDrive Solar Wiring Diagrams

Franklin Electric SubDrive Solar Wiring Diagrams

Array

Advertisement

Quick Links

SubDrive Solar
Array Wiring Diagrams
SOLAR SUBMERSIBLE
PUMP CONTROLLER
P U M P C O N T R O L L E R
S O L A R S U B M E R S I B L E

Advertisement

loading

Summary of Contents for Franklin Electric SubDrive Solar

  • Page 1 SubDrive Solar Array Wiring Diagrams SOLAR SUBMERSIBLE PUMP CONTROLLER P U M P C O N T R O L L E R S O L A R S U B M E R S I B L E...
  • Page 2 Use the SubDrive Solar controller only with Franklin Electric 4-inch submersible motors as specified in SubDrive Solar manual (see Table 6, pg. 26). Use of this unit with any other Franklin Electric motor or with motors from other manufacturers may result in damage to both motor and electronics.
  • Page 3 SubDrive Solar Wiring Diagram – 6 Panel Notes: Maximum Vmpp not to exceed 330VDC Maximum Voc not to exceed 410VDC Based on panel: Wmpp – 195 watts Vmpp – 36 Vdc Voc – 45 Vdc Pump/Motor 16 Amp 3 Phase...
  • Page 4 SubDrive Solar Wiring Diagram – 12 Panel Notes: Maximum Vmpp not to exceed 330VDC Maximum Voc not to exceed 410VDC Based on panel: Wmpp – 195 watts Vmpp – 36 Vdc Voc – 45 Vdc Pump/Motor 16 Amp 3 Phase...
  • Page 5 SubDrive Solar Wiring Diagram – 6, 7, 8 & 9 Panels Notes: Maximum Vmpp not to exceed 330VDC Maximum Voc not to exceed 410VDC Based on panel: Wmpp – 195 watts Vmpp – 36 Vdc Voc – 45 Vdc Pump/Motor...
  • Page 6 SubDrive Solar Wiring Diagram – 14 Panel Notes: Maximum Vmpp not to exceed 330VDC Maximum Voc not to exceed 410VDC Based on panel: Wmpp – 195 watts Vmpp – 36 Vdc Voc – 45 Vdc Pump/Motor 16 Amp 3 Phase...
  • Page 7 SubDrive Solar Wiring Diagram – 16 Panel Notes: Maximum Vmpp not to exceed 330VDC Maximum Voc not to exceed 410VDC Based on panel: Wmpp – 195 watts Vmpp – 36 Vdc Voc – 45 Vdc Pump/Motor 16 Amp 3 Phase...
  • Page 8 SubDrive Solar Wiring Diagram – 18 Panel Notes: Maximum Vmpp not to exceed 330VDC Maximum Voc not to exceed 410VDC Based on panel: Wmpp – 195 watts Vmpp – 36 Vdc Voc – 45 Vdc Pump/Motor 16 Amp 3 Phase...