6 Servicing procedures
Cooking programs that can be used in emergency mode (easyTouch)
The following table summarizes which cooking programs can be operated in emergency mode for dif‐
ferent errors:
Error
Error
code
code
33
E01.0
24
E02.0
36
E04.0
21
E15.0
E22. .. CTC faulty X
6-9
3
E25.0
47
E83.0
48
-
x
Operation possible
-
Operation not possible
User manual
Display
text
Low water
-
-
Overtem‐
X
up to
perature in
140 °C
electrical
area
Cooling fan
X
up to
malfunc‐
140 °C
tion
Overtem‐
-
-
perature in
condenser
X
Condenser
X
up to
probe bro‐
180 °C
ken
Algo error
X
X
IDM error
X
X
up to
--
up to
180 °C
180 °C
up to
up to
up to
140 °C
140 °C
140 °C
up to
up to
up to
140 °C
140 °C
140 °C
up to
-
up to
180 °C
180 °C
X
X
X
up to
up to
up to
180 °C
180 °C
180 °C
X
X
X
X
X
X
76
Comments
No program that uses
steam
Let the appliance cool
down
Finish cooking the prod‐
uct at a low cooking tem‐
perature
Let the appliance cool
down
Finish cooking the prod‐
uct at a low cooking tem‐
perature
Increased water consump‐
tion through constant cool‐
ing of the condenser
No operation using the
CTC
Increased water consump‐
tion through constant cool‐
ing of the condenser
Error usually cleared by
switching the appliance off
and on