Appendix A – ME-ARC Compatibility Matrix
Main
Menu
Heading/Item
06A Battery Type
06B Absorb Done
06C Max Charge Rate 0-100%
06D Max Charge
Time
06
06E Bulk Start
PT
Setup
06F PT Aux Relay
06G PT Alarm
06H PowerSave PT
Display
*
12-volt values shown; for 24v systems – x2, for 48v systems – x4.
** These settings return to the factory default setting when power to the remote is removed.
ME-ARC Compatibility Matrix Notes:
[1] Not available on MM/MM-E/MM-AE/MMS/MMS-E models.
[2] Activate AC Couple Mode using Battery Type: Custom with MS-PAE Series ≥Version 4.1.
[3] The AC meter displays are only accurate when used with MS-PE, MS-PAE or MSH Series
inverters. The meters do not display unless the inverter is ≥ Level 4.
[4] Level 2 and 3 inverters can be used, but:
Level 2 inverters are limited from 1.0-4.5 hours,
Level 3 inverters <Version 4.1 are limited from 1.0-6.5 hours,
Level 3 inverters ≥Version 4.1 (and MMS Version 1.5) are limited from 1.5-6.5 hours.
Any setting outside these limited ranges are not recognized and reverts to the inverter's
default absorption time (2.0 hours).
[5] Requires ≥Level 4 to display.
[6] SOC features require the ME-BMK (Battery Monitor Kit) to be installed.
[7] To manually turn the generator on with the remote, a ME-AGS-N Version 5.0 or higher is
required.
Page 133
Features/Settings
Menu
CC/
CV
Time = 0.1-25.5 Hrs
Amps = 0-250 ADC
SOC = 50-100% [6]
OFF, 0.1-25.5 Hrs
Daily/SunUp = YES, NO
Volts = OFF, 9.0-16.0*
SOC = OFF, 50-99% [6]
Engage Volts = 8.0-16.6*
Engage Delay = 0-127s, 1-127m
Disengage Volts = 8.0-16.6*
Disengage Delay = 0-127 Sec,
1-127 Min
ON Volts = 8.0-16.6*
ON Delay = 0-127s, 1-127m
OFF Volts = 8.0-16.6*
OFF Delay = 0-127s, 1-127m
OFF, 1 - 60 Min
Selections/
Adjustments Range
Amps = 0-250 ADC
Max CC/CV Time =
OFF, 0.1-25.5 Hrs
Recharge = 9.0-16.0* V
Hold CV Chg VDC
Model/
Level
Default
Required
20 ADC
12.0 Hrs
≥Level 1
12.0*
2.0 Hrs
≥Level 1
20 ADC
100%
≥Level 1
100%
≥Level 1
12.0 Hrs
YES
≥Level 1
12.0*
80%
10.0*
10 Sec
≥Level 1
14.0*
10 Sec
10.0*
10 Sec
≥Level 1
14.0*
10 Sec
≥Level 1
15 Min