MAINTENANCE
4.12.8 MACHINERY HOUSE DOORS - INSPECT AND LUBRICATE DOOR
HINGES
Provide adequate working platform for safe access to the
rear machinery house doors (2).
Check all door hinges (3) for good condition and proper
fastening to their carrier frames. If cracks or distortion at
the weld area of the hinges are found corrective action
must be taken.
Legend for illust. Z25096
(1)
Radiator doors (on Diesel engine powered shovels only)
(2)
Rear doors of machinery house
(3)
Door hinges
(4)
Grease fitting
(5)
Cotter pin
Lubricate all door hinges (3) at grease fittings (4).
Check to make sure that the hinge pins are properly secured
with cotter pins (5).
WARNING
4.12 EVERY 1000 OPERATING HOURS OR EVERY 6 MONTH