MAINTENANCE
4.9 EVERY 50 OPERATING HOURS OR WEEKLY
TRAVEL GEAR BOX - CHECK OIL LEVEL
Illustration Z25244:
Remove oil level gauge (2) and wipe it clean. Screw in the gauge
and remove again. Oil level should be at the upper mark of gauge
(2). If necessary add oil through filler opening (3). Insert gauge (2)
and filler plug (3) and tighten securely. Check breather filter (18),
illustration Z25243 on page 349 for restriction. If necessary,
remove breather filters, blow out with compressed air from inside
to outside and reinstall.
MOTOR ADAPTER HOUSINGS - CHECK OIL
LEVEL
Check oil level by removing oil level plugs (8).
Oil level should be at lower edge of openings (8). If necessary,
remove connector (9) for breather filter line and add oil through
filler opening. Install level plugs (8) and screw in breather filter line
connectors (9).
Check breather filter (19), illustration Z25243 on page 349 for
restriction. If necessary, remove breather filters, blow out with
compressed air from inside to outside and reinstall.
FINAL DRIVE HOUSING - CHECK OIL LEVEL
Remove oil level gauge (13) and wipe it clean. Screw in the
gauge and remove again. Oil level should be at the upper mark of
gauge (13). If necessary add oil through filler opening (14). Insert
gauge (13) and filler plug (14) and tighten securely. Check
breather filter (20), illustration Z25243 on page 349 for restriction.
If necessary, remove breather filters, blow out with compressed
air from inside to outside and reinstall.