Komatsu PC5500-6 Operation & Maintenance Manual page 255

Hydraulic mining shovel
Hide thumbs Also See for PC5500-6:
Table of Contents

Advertisement

OPERATION
ADJUSTMENTS OF THE CENTRAL LUBRICATION
SYSTEM
(For factory installed system only)
The following adjustments can be made in the service menu of
the ECS system:
Level 4: Service Menu / Settings
*PAUSE TIME
*MONITORING TIME
*PRESSURE RELIEF TIME
*LUBE CYCLE COUNTER
"ELECTRONIC MONITORING AND
Refer to section
CONTROL SYSTEM ECS"
CENTRAL LUBRICATION SYSTEM "CLS"
procedure.
Repairs on the Central Lubrication System with the Engines
running or with the Engines OFF and Main Switch Key in ON
position
If repairs under the above conditions have been carried out it is
necessary to reset the control circuit of the lubrication system by
actuating the rotary switch (1), illust. (Z 21762) for a full lube
cycle.
If this manually actuated lube cycle is not being carried out, the
fault message "LUBE SYSTEM FAILURE" will remain on the ECS
display (3).
Resetting of the lube system control circuit can also be done by
shutting down the engine and switching OFF the main switch key.
NOTICE
For more information regarding inspection, trouble shooting
and maintenance of the lubrication system, refer to the sepa-
rate manual LUBRICATION SYSTEMS in volume 2 binder.
for description of adjustment
3.16 OPERATION OF THE LUBRICATION SYSTEM
255

Advertisement

Table of Contents
loading

This manual is also suitable for:

15027

Table of Contents