Komatsu PC5500-6 Operation & Maintenance Manual page 351

Hydraulic mining shovel
Hide thumbs Also See for PC5500-6:
Table of Contents

Advertisement

MAINTENANCE
4.9.3
PTO's (PUMP DISTRIBUTOR GEARS) AND OIL RESERVOIR - CHECK
OIL LEVEL
Legend for illustration Z 20696
(1)
Oil level gauge
(2)
Oil filler plug
(3)
Breather filter
(4)
Oil drain plug
(7)
Oil collector reservoir for adapter housings of
hydraulic pumps for fan drives
(8)
Breather filter with oil level gauge
(9)
Adapter housings for main hydraulic pumps
(10)
Oil level plugs
(11)
Oil filler plug with breather pipe
(12)
Oil drain plug
PUMP DISTRIBUTOR GEARS, CHECK OIL LEVEL:
1. Unscrew level gauge (1) and wipe it clean.
2. Insert gauge (1), but DO NOT screw in, see detail (A).
3. Remove level gauge and read the oil level. The oil level
should be between the "MIN" and "MAX" mark. If necessary,
add oil through filler opening (2) up to the "MAX" mark on
gauge (1).
NOTICE
If the oil level is above the "MAX" mark, drain the oil down
until the oil level is at the "MAX" mark. Too much oil in the
pump distributor gear will cause aeration of the oil.
4. Insert gauge (1) and tighten securely. Remove breather filter
(3). Blow out with compressed air from inside to outside and
reinstall.
4.9 EVERY 50 OPERATING HOURS OR WEEKLY
351