Komatsu PC5500-6 Operation & Maintenance Manual page 419

Hydraulic mining shovel
Hide thumbs Also See for PC5500-6:
Table of Contents

Advertisement

MAINTENANCE
High-Strength Bolt Connections (continued)
Excavators with Electric Prime Mover
Check condition and fastening of slip ring unit (01),
illust. Z 20616
Reference No.:
((04)
M16
(05)
M16
(07)
M16
* = Wrench size
Re-tighten mounting bolts to their correct torque and replace
missing or damaged bolts.
Bolt size
Grade
mm
10.9
8.8
8.8
4.12 EVERY 1000 OPERATING HOURS OR EVERY 6 MONTH
SW *
Tightening torque
mm
Nm
24
265
24
180
24
180
Qty.
4
4
4
419