OPERATION
Data Transfer from Protocol and Statistics Memory
to various Downloading Equipment
The illustration (Z 20731) shows typical arrangement of several
downloading equipment connected to the text display interface
plug socket (X27).
Legend for illust. (Z 20731)
(1)
Text display unit on instrument panel (E35)
(2)
Plug socket (serial interface X27) for connecting
data transfer cable to units (4, 5, 6 or 9)
(3)
Plug socket for connecting current supply cable to
units (5 or 6)
(4)
MODULAR MINING field computer system "MMS"
(5)
Printer
(6)
Memory Card System "MCS". As a special equip-
ment, this system can also be installed in the instru-
ment panel ex works.
(7)
Memory card
(8)
Protective box for memory card
(9)
Laptop or PC
(10)
Soft- and hardware package for PROSTAT operation
program
(11)
Data transfer cable (VL3)
(12)
Adapter for 25 pin interface on PC or laptop
(13)
3,5" disk PROSTAT software
(14)
Instruction manual PROSTAT (Service Bulletin No.
21-538)
(15)
Change-over switch for connecting the internal out-
put channel to plug socket (2) or to the onboard
MCS system (6) if so equipped
(E6)
Programmable Logic Controller "PLC"
(VL4)
Data transfer cable to Memory card system (6)
(VL5)
Current supply cable to Memory Card System (6)
(VL6)
Data transfer cable to printer (5)
(VL7)
Current supply cable to printer (5)
(VL8)
Data transfer cable to field computer system (4)
REMARK
The downloading units shown in illust. (Z 20731) are special
equipment.
More information to these units on request.
3.4 ELECTRONIC MONITORING AND CONTROL SYSTEM ECS