VERSION 4 LPX AUTOMATED TREATER CONNECTIONS
16. Have a certified electrician provide power to the seed treating system.
Provide convenient shutdown switches, comply with local electrical codes and
ensure that the system is properly grounded and bonded. The USC system must
be connected to the same electrical requirements as specified in the main control
panel on the power requirement tag, or the electrical schematic shipped with the
piece of equipment. This will power the USC LPX seed treater and any attached
conveyors.
NOTICE
Flexible conduit is recommended for main power supply.
AVIS
Conduit flexible est recommandé pour l'alimentation principale.
17. Provide 110V single phase power to the main control panel, I/O control panel and
the pump stand(s). If any of the panels are located in the hazardous area
described in the installation section (see page 19), all 110VAC connections must
be hard wired to a listed type 4 rated enclosure.
18. Reverse the previous steps when removing the machine from its working position.
LPX SEED TREATER
VERSION 4 MAIN
CONTROL PANEL
VERSION 4
AUTOMATED
TREATER
CONTROL PANEL
Page 29