VERSION 4 MAIN CONTROL PANEL CONNECTIONS
2
3
1. Attach the Main Control Panel to the control panel stand using the provided
hardware. Determine the permanent location you will be operating the system
from, then anchor the stand to the floor. The panel may also be mounted to a wall.
2. There are six MODBUS TCP Ethernet connectors on the Main Control Panel
(MCP). If the installation has a version 3 four pump or twelve pump controller
panels, connect them using one of the Ethernet Ports. These are also used
for connecting scale heads, printers, etc.
3. Connect a cable with four pin connector to one of the three Powerlink connectors
on the MCP. Connect the other end to the Powerlink connector on the closest
control panel. Repeat this process until all control panels are connected.
It may be MCP to Treater to Tri-Flo® to Bin Site panel. The order or number
of devices is not important. It is important that all panel are connected.
All pump stand control panels will need to connected in a similar configuration.
4. Connect the red cable to the PJESTOPA on the Main Control Panel (MCP) and
then to the PJESTOPB on the next panel that is closest to the MCP. Repeat this
process until all control panels are connected in a daisy chain configuration.
It may be MCP to Treater to Tri-Flo® to Bin Site panel. The order or number
of devices is not important. It is important that each cable is ran from an
A connection to a B connection (never A to A or B to B), and that no control panel
is left out of the chain. Connect the two red plugs onto each of the remaining open
PJESTOP connectors on the first and last panel.