Troubleshooting Rechargeable Battery 12.2; Troubleshooting Battery Charger - Wacker Neuson APS1030 Operator's Manual

Table of Contents

Advertisement

12.2
Troubleshooting rechargeable battery
Pictogram
Status control light
Control light rechargeable
battery error is lit.
Overtemperature/undertem-
perature control light lights
up.
Diagnosis control light lights
up.
* Have this work carried out by a service partner.
12.3

Troubleshooting battery charger

Fault
The rechargeable battery is not
charged.
[en] | 02/2022 | 5100060593 | APS | Operator's Manual

Troubleshooting rechargeable battery 12.2

Possible cause
Contact error of connection
strip.
Activating the rechargeable
battery too quickly.
Incorrect sequence when
activating the rechargeable
battery.
Hardware error or software
error.
Temperature error (too high
or too low temperature).
The rechargeable battery
was disabled due to a fault.
WARNING
Danger to life due to unauthorized troubleshooting!
► If faults occur on this machine which are not described in these oper-
ating instructions, contact the manufacturer.
► Do not rectify faults on your own.
Possible cause
Connection plug not connected cor-
rectly.
Supply cable not connected to
power source.
The rechargeable battery is defect-
ive.
Battery charger is defective.
Troubleshooting
Remedy
Clean and if necessary dry the
contacts.
Deactivate the rechargeable bat-
tery and only activate it again
after 10 - 15 seconds.
First activate the rechargeable
battery and then start the ma-
chine.
Activate rechargeable battery
again and acknowledge error by
push button.
Have the rechargeable battery re-
paired.*
Operate the rechargeable battery
only within the permissible tem-
perature range.
Allow the equipment to cool down
if necessary.
Activate rechargeable battery
again.
Have the rechargeable battery re-
paired.*
Remedy
Connect connection plug correctly.
Plug supply cable into power source.
Contact service partner.