Step 2 Pull the cable to the copper bar to which the cable is to be connected, determine
the cable length, and mark the cable at the position where the cable is to be cut.
Step 3 Pull the marked cable out of the cabinet, cut the cable from the marked position,
strip the cable, and crimp a terminal.
Figure 3-16 Preparing a cable terminal outside the cabinet
Choose an appropriate cabling route based on the actual situation. The figure is for reference
only.
Step 4 Connect the cable with a crimped terminal to the corresponding copper bar.
Step 5 Clear sundries inside the cabinet.
----End

3.2.5 Routing Cables

3.2.5.1 Top Cable Routing

Context
● If cables need to be routed through holes, remove cable covers for power
● This section describes cable connections when the mains input and bypass
● Determine the cable cross-sectional area and quantity based on the section
Issue 06 (2022-01-27)
NO TE
NO TICE
cables from the bypass cabinet and drill holes in the covers. After drilling holes,
attach grommet strips on the hole edges to protect cables. Reinstall the covers
on the cabinet.
input use different power sources. When they use the same power source, there
is no need to remove the copper bars between the mains and bypass input
terminals or connect the bypass input power cables.
"Preparing Power Cables" and site requirements. The figures are for reference
only.