14.1

MECHANICAL

The dimensions of the mountings are given in figure 7 and figure 8.
The pump is provided for assembly and therefore it has to be fastened with screws.
Install the pump so that the fan can draw in sufficient cooling air.
Install the pump so that accidental finger contact with the fan is impossible.
Mounting the pump at the highest place in system and/or with pump head downside so that conden-
sate cannot be assembled inside the head - this increases the operating time.
Figure 7
Dimensions (mm) pump MP47..
14.2

ELECTRICAL

When making the electrical installation the safety regulations must be observed. In particular make sure that the
electricity supply is isolated before trying to connect the pump.
Warning
16
The diaphragm pumps type MP47, MP47/R, MP47-Z, MP47-Z/R, MP47/D
must not be used in hazardous areas.
When connecting the equipment, make sure that the supply voltage is
identical with the information provided on the model type plate. The sup-
ply voltage is only allowed to deviate max. +6 % respectively -10 % from
the indication on the model type plate.
MP47 | 1.01.02
www.mc-techgroup.com