Mp47; Application; Description; Figure 5 Pump Mp47 - M&C MP Series Instruction Manual

Analytical diaphragm pump
Hide thumbs Also See for MP Series:
Table of Contents

Advertisement

11
MP47.../D INCL. DOUBLE DIAPHRAGM SAFETY SYSTEM/DIAPHRAGM BREAKAGE
MONITORING
11.1

APPLICATION

There are some applications - for example when processing with strong aggressive, high toxic or hydrocarbon
contaminated gases, it is necessary to install a high-level safety system. For these applications, it is important to
monitor continuously the tightness of the pump diaphragm.
11.2

DESCRIPTION

M&C provides for the series MP47... pump as option a diaphragm breakage monitoring. Below the pump dia-
phragm, a monitoring area integrated as a pressure close area with a second diaphragm. Both diaphragms form a
sealed safety area. Via an optional flow sensor and an external compressed
medium, i.e. air or N
, it is possible to monitor continuously the tightness of the diaphragm.
2
Dimensions of analytical diaphragm pump with a double diaphragm safety system type MP47.../D.
18
80
Figure 5
Pump MP47 .../D with the standard motor
www.mc-techgroup.com
4xM6 10 tief
20
G1/4"
G1/8

MP47 | 1.01.02

34
180
124
66
110