Technical Support Contacts - Firstech CM6200 Installation Manual

Starter system
Hide thumbs Also See for CM6200:
Table of Contents

Advertisement

CM6200 Install Guide
On the brain, how do I set the auxiliaries?
A: You must have an Option Programmer (FT-OP500-KIT) to set the auxiliaries on the CM4000, CM4200-
DX, CM4300, CM5000, CM5200, CM6000, CM6200 and CM6300. First choose two POC wires on
CN3 that you are not using. With the OP500 go into the Special Option Group 2 and set those POC's to
Aux 1 and Aux 2. Review the "Special Option Group" programming section of this manual. On the CM6
Series control modules, Auxiliary 1 is pre programmed on CN3, Pin 19, Violet Wire.

Technical Support Contacts

Firstech technical support is reserved for authorized dealers only.
Monday - Friday:
Email:
Web:
Wire Diagrams
Click on the "Installogy Access Client" link found on your desktop. If you are a qualified dealer and unable
to access this site, call your sales representative or the number above.
Copyright 2012 Firstech, LLC.
888-820-3690
(8:00 am – 5:00 pm Pacific Coast Time)
support@compustar.com
www.compustar.com/dealersupport
Starter System
www.firstechonline.com | www.compustar.com
CM6200
Page 36

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CM6200 and is the answer not in the manual?

Subscribe to Our Youtube Channel

Table of Contents