CM6200 Install Guide
Feature
Tach Sensing Method
2-01
Turbo Timer
2-02
Diesel Timer
2-03
Trigger Start
2-04
Cold or Hot Start with Thermistor
2-05
Assembly
Timer Start, or, Minimum Interval
2-06
Between Cold Starts
2-07
Remote Start Runtime
Temperature of Cold Starting
2-08
Temperature of Hot Starting
2-09
Engine Sensing
2-10
Advanced Tachless
2-11
Crank Time
2-12
Timer Mode
2-13
Feature
Parking lights While Remote
3-01
Started
Confirmation Chirps
3-02
Dome Light Delay
3-03
Starter-Kill Relay
3-04
Factory Style Alarm
3-06
Horn Output
3-08
Siren Output
3-09
Valet
3-10
3-11
Auxiliary Settings Mode
VAC (Ventilation, Air
3-12
Conditioning)
Defroster Temperature Control
3-13
Copyright 2012 Firstech, LLC.
Option Group 2
Default Setting - I
Optional Setting - II
Optimal Tach Method
Previous Tach Method
Off
Wire
3~99sec (12sec Default)
Off
Off
3 Hour (4 minute run-
1.5 Hour(4 minute run-
time, double for Diesel)
time, double for Diesel)
15 Min
-10° C / 14° F
25° C / 77° F
Tach
Off
+0.2 Seconds to Crank
Standard
Off
Option Group 3
Default Setting - I
Optional Setting - II
Constant Output
Medium (30 ms)
Off
Anti-Grind + Starter Kill
On
On Double Lock Only
On Lock and Unlock
On Lock, Unlock, and
On Double Lock Only
Start
Key 5 times, or Remote
Key 5 times or Remote
(I+III) while Ignition is
On
Disabled
Above 100 Degrees F
Above 90 Degrees F
Standard
Only below 32 degrees F
www.firstechonline.com | www.compustar.com
Optional Setting - III Optional Setting - IV
Low Threshold Tach
2 Min
Single Pulse
Double Pulse
Cold Start
Reservation (Runtime
set by 2-7) 2 Way LCD
Remotes Only
25 Min
-20° C / -4° F
-5° C / 23° F
30° C / 86° F
35° C / 95° F
No Connection – No
Alternator
Tach Sensing
(Tachless Mode Only)
On
+0.6 Seconds to Crank
Time
On
Optional Setting - III Optional Setting - IV
Flashing Output
Short (15 ms)
Normal (60 ms)
5 sec
Anti-Grind + Passive
Anti-Grind
Starter Kill
Off
On Lock, Unlock, and
On Lock and Unlock
Secure Valet
(I+III)
(Default code 3,3)
Enabled
Above 80 Degrees F
Only below 42
degrees F
Starter System
Method
1Min
4 Min
7 sec
GM Ignition Delay
Triple Pulse
Hot Start
Cold and Hot Start
24 Hour Repeat with
Cold Starting of 2-8
(Runtime set by 2-7) 2
Way LCD Only
45 Min
3 Min
-15° C / 5° F
40° C / 104° F
No Connection – 1.5
Second Crank
(Not for Manual
Transmissions)
(-)0.2 Second Crank
Time
Time
Off
45 sec
Auto
On Double Lock and
Start
Start
On Double Lock and
Start
Above 90 Degrees
Latched for Runtime
Page 20
Need help?
Do you have a question about the CM6200 and is the answer not in the manual?