Technical Data - Dometic CoolAir SPX1200I Installation Manual

Parking cooler
Hide thumbs Also See for CoolAir SPX1200I:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
EN
5. Press the
button to change the setting.
6. Use the
or
7.
Press the
button to save the settings.
The set value is saved and is then applied when the system is restarted. You are then returned to the menu and can
select another menu item by pressing the

9 Technical data

Cooling capacity
Rated input voltage
Input voltage range
Operating temperature range
Current consumption
Low-voltage cut-off
Dimensions (W x H x D)
Weight
Inspection/certification
22
button to select 1 for calibrating the tilt sensor.
or
button.
CoolAir SPX 1200 parking cooler
with SPX 1200IC rear panel evaporator unit
1200 W
24 V
20 V  ... 30 V
5 °C ... 52 °C
12 A ... 22 A
Configurable
Compressor unit 346 mm × 560 mm × 156 mm
Evaporator unit 648 mm × 278 mm × 144 mm
Evaporator unit 15 kg (including connection lines)
Compressor unit 21 kg (without fastening frame)
 

Advertisement

Table of Contents
loading

Table of Contents