3.
Note The level for the low voltage shut-down should not be set any lower than the minimum battery
voltage required to be able to start the engine under any conditions. As a rule that should be no less
than 22 V.
Use the
or
The low voltage shut-down setting can be adjusted in 0.1 V increments from 20 V to 23.5 V.
4. Press the
button to save the settings.
The set value is saved and is then applied when the system is restarted. You are then returned to the menu and can
select another menu item by pressing the
P.02: Unit for temperature display
The system can display the room temperature in °C or °F. This parameter can be configured.
1.
Switch to the configuration mode.
The display shows P.01 and the
2. Press the
button to change the setting
The current setting is displayed.
3. Use the
or
The display shows P.02 and the symbol lights up.
4. Press the
button to change the setting.
The code for the current setting is displayed:
0: °C 1: °F
5. Use the
or
6. Press the
button to save the settings.
The set value is saved and is then applied when the system is restarted. You are then returned to the menu and can
select another menu item by pressing the

9 Technical data

Cooling capacity
Rated input voltage
Input voltage range
Operating temperature range
Current consumption
Low-voltage cut-off
button to select the voltage level for low voltage shut-down.
symbol flashes.
button to select the menu item P.02.
button to select the desired temperature unit.
or
button.
or
button.
CoolAir SPX 1200 parking cooler
with SPX 1200IC rear panel evaporator unit
1200 W
24 V
20 V  ... 30 V
5 °C ... 52 °C
12 A ... 22 A
Configurable