OPERATION
1.
Before starting the engine, check that fuel control lever
(1) is at the low idling position.
2.
Pull fuel control lever (1) to a position midway between
the low idling and full speed positions.
3.
Insert the key into starting switch (2) and turn the key to
the ON position.
4.
Carry out preheating.
There are the following two ways of carrying out preheating. First use the convenient automatic preheating
system.
For operating method, see the section of "AUTOMATIC PREHEATING (PAGE 3-63)" and "MANUAL PRE-
HEATING (PAGE 3-64)".