DSC OPERATION
D Self Check Test
The Self Check test function sends
transmit DSC signals to the receive AF
circuit to compare and check the TX
and RX signals at the AF level.
1.
Push [MENU].
2. S elect "Self Check test," then push
[ENT].
( D SC Settings > Self Check Test)
3. P ush [ENT] to start the DSC loop
test.
• I f the transmit DSC and receive DSC
signals match, "OK" is displayed.
4.
P ush [MENU] to return to the Main
screen.
64
D Selecting the DSC procedure
(For only the USA version.)
Select weather or not to enable the
transceiver handling more than 2 tasks
at same time.
See page 29 and page 30 for the
Single task and Multiple task details.
1.
Push [MENU].
2. S elect "Procedure:," then push
Rotate
[ENT].
( D SC Settings > Procedure:)
+
Push
3. Select the option, then push [ENT].
Push
• Single: T he transceiver handles a
single task (Default).
• Multiple: T he transceiver can handle
up to 7 tasks at same time .
4.
P ush [MENU] to return to the Main
screen.