Working at high altitudes
In high altitude areas, the air-fuel mix in a standard carburetor is relatively thick, so the engine operating performance
will reduce, while the fuel consumption increases. At this point you can adjust the main jet on the carburetor (smaller),
while adjusting the ratio-mixing screw, then you can change the performance of the engine in high altitude areas. If
you are always using the generator at an altitude of 1500 meters or above, please let a
agent modify the carburetor.
Even with the appropriate main jet, the engine power will still drop by 3.5% as altitude increases every 305 meters. If
you do not make these adjustments, the impact of altitude on the power will be greater.
 If the main jet is designed for high altitude areas but is operating at low altitudes, it may
cause decreased output power, overheating, or serious engine damage due to thin air-fuel
mix.

7.Operating the Generator

 In order to prevent electric shock caused by improper use, the generator should be
grounded. Connect a thick cable between the ground terminal of the generator and the
external ground source.
 If the unit is used as a backup power source for a building, the connection of the
generator to its power system shall be carried out by a professional electrician and
must comply with the applicable laws and regulations. Otherwise, the power of the
generator may impact on the public circuit. If the power company employees or
others touch the wire in the meantime, it will lead to injury or even death; At the
same time, due to the impact of electricity, the generator may explode, burn or cause
the building electricity equipment to fire.
 When the generator is running continuously, do not exceed the rated power. In other cases,
pay attention to the total power of the connected equipment.
 Do not exceed the rated current of the socket.
 Do not use the generator for purposes that it cannot achieve. Please also observe the
following requirements:
Do not parallel generators with unauthorized units or use unauthorized parallel power
cables or boxes.
Do not extend the exhaust pipe
 If a longer cable is required, use a flexible cable for with rubber sleeve (the cable should
comply with IEC standards).
 The length of the extension cable is limited, the cable of 2mm
of 3mm
2
 The generator should be away from other electric wires or cables, such as: electricity
transmission network.
is 100 meters long.
BE CAUTIOUS
WARNING
BE CAUTIOUS
is 60 meters long; the cable
2
BUILDER SAS
authorized
19