5) Circuit Breaker
The circuit breaker will automatically switch OFF if there is a short circuit or a significant overload
of the generator at the receptacle. If the circuit breaker is switched OFF automatically, check that
the appliance is working properly and does not exceed the rated load capacity of the circuit before
switching the circuit breaker ON again. The circuit breaker may be used to switch the generator
power ON or OFF.
6) Ground Terminal
The generator ground terminal is connected to the panel of the generator, the metal non-current
carrying parts of the generator, and the ground terminals of each receptacle. Before using the
ground terminal, consult a qualified electrician, electrical inspector or local agency having
jurisdiction for local codes or ordinances that apply to the intended use of the generator.
7) Oil Alert System
The oil alert system is designed to prevent engine damage caused by an insufficient amount of oil
in the crankcase. Before the oil level in the crankcase can fall below a safe limit, the oil alert
system will automatically shut down the engine (the engine switch will remain in the ON position).
The oil alert system shuts down the engine and the engine will not start. If this occurs, first-check
engine oil.

4. GENERATOR USE

1) Connections to a Building's Electrical System
13