 If the generator cannot be started for the first time when the oil is added, or the oil is changed,
the oil alarm indicator flashes when pulling the start handle, at this time, the generator should
be shaken back and forth to ensure that the float of the oil alarm floats. If the generator still
does not start, please follow the troubleshooting instruction above.
 Make sure no fuel spills around the spark plug. Spilled fuel may catch fire.
Check spark plug:
1. Remove the anode cap and clean the dirt around the spark plug.
2. Remove the spark plug and insert the spark plug into the anode cap.
3. Connect the spark plug side electrode with wire to the metal part of the engine to ground. (You can use the DC
output wire to replace the wire. Use one end of the clip to clamp the metal part of the engine, and the other end
connect to the side electrode of the spark plug.)
4. Pull the start handle, spark should jump from the gap.
 Ensure that the engine is cooled down when you check the spark plug, or the high temperature
of the engine and spark plug will cause burns.
Connected device does not work
Is the output indicator ON or OFF?
ON
Does the connected device
work?
OFF
Is overload indicator ON?
ON
亮着
Yes
No
NOTICE
NOTICE
NOTICE
OFF
Return the generator to an authorized
dealer for further assistant.
Shut off the generator and wait until
the overload indicator turns off, then
start again or press the reset button to
restart the generator.
Return the generator to an authorized
dealer for further assistant.
1) Replace the device
2) Get the device repaired.
Overload indicator is ON