1.4. Air Requirements

The air supply to the counterbalance should be clean and liquid water should not be present.
If nitrogen is used, it must be 99.99% pure and filtered to 0.25 microns. [Recommended]
l
If compressed air is used, it must be filtered to 0.25 microns, dry to 0º F dew point, and oil free.
l
The maximum allowable input pressure specification is 0.6 MPa (87 psi).
The low friction air cylinder consumes air as described in
Figure 1-2:
Counterbalance Air Flow vs. Counterbalance Pressure
Figure 1-3:
Air Inlet Location
20
Figure
1-2.
Hardware Manual
www.aerotech.com