CHAPTER 7
This chapter describes the setting procedures of the A/D converter module.
After writing the contents of new module, switch settings, parameter settings and auto refresh settings into the CPU module,
reset the CPU module, switch STOP → RUN → STOP → RUN, or switch ON the power supply, to validate the setting
contents.
7.1

Addition of Modules

Add the model name of A/D converter modules to use on the project.
(1) Addition procedure
Project window
Module Selection
Mount Position
Title Setting
VARIOUS SETTINGS
[Intelligent Function Module]
Item
Module Type
Set "Analog Module".
Module Name
Select the name of the module to connect.
Mounted Slot No.
Set the slot No. where the module is connected.
Specify start X/Y
The start I/O number (hexadecimal) of the target module is set, according to
address
the slot No. Setting any start I/O number is also possible.
Title
Set any title.

CHAPTER 7 VARIOUS SETTINGS

"New Module"
Description