Switch Board, but it wasn't activated yet.
Please provision IP address of the Switch Board via EMS
and lock/unlock it in order to activate new software.
7.
When the new software is uploaded, provision the IP address of the Switch Board via
the EMS and LOCK/UNLOCK it.
8.
Wait approximately 10 minutes until the ES Board becomes ENABLED. Verify this in
the EMS.
20.2
Troubleshooting
If Ethernet Switch Board doesn't have IP address, take these 3
steps prior to installing new software on it:
1.
Connect to the Switch Board's RS232 console.
2.
Log in using the username: admin and password: password.
Escape character is '^]'.
PTI CPC4411 (from application)...
login: admin
Password: password
#
3.
Configure the IP address on Ethernet Switch board (note that this configuration does
not survive reset, hence you should immediately proceed to the software installation as
described above).
# ip config sw0 10.1.1.35
Installation, Operation, Maintenance Manual
212
Media Gateway 3500
Document # LTRT-90704