Cooktop Hoods
Planning Information
Wolf Cooktop Ventilation Hoods are recommended for use
with Wolf Induction and Gas Cooktops, and Modules. For
Wolf Ranges and Rangetops, a Wolf Pro Ventilation hood is
recommended.
These hoods have a telescopic chimney flue. A flue exten-
sion is available through an authorized Wolf dealer.
Installation of the Cooktop Hood should be 762 mm to
914 mm from the bottom of the hood to the countertop.
Wall and island hoods require an internal or remote blower
assembly, avail able through an authorized Wolf dealer.
Refer to Ventilation Suggestions on pages 110–112.
Cooktop Hoods have a vertical discharge with 152 mm
round duct.
Consult a qualified HVAC professional for specific installa-
tion and ducting applications.
98 | English
ELECTRICAL REQUIREMENTS
Installation must comply with all applicable electrical
codes and be properly grounded (earthed).
For wall hoods, locate the electrical supply within the
shaded area shown in the illustration below. For island
hoods, locate the electrical supply on the ceiling inside the
top of the hood. A separate circuit servicing only this appli-
ance is recommended.
ELECTRICAL REQUIREMENTS
Electrical Supply
Service
E
457
mm
762 mm
914 mm
TO
BOTTOM EDGE TO COUNTERTOP
Electrical location for all wall hoods
220-240 V AC, 50 Hz
220 V AC, 60 Hz
1.9 A

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents