Planning Information
The Vacuum Seal Drawer can be installed in a standard or
flush inset application. Finish the edges of the opening.
They may be visible when the drawer is open.
For standard installations, the face trim will overlap stiles
and rails. Refer to the chart below.
For flush inset installations, a minimum 3 mm reveal is
required on all sides. To ensure consistent reveals, each
corner of the opening must be exactly 90°.
INSTALLATION REQUIREMENTS
Minimum Base Support
TRIM OVERLAP
Top
Bottom
Sides
68 | English
ELECTRICAL REQUIREMENTS
Installation must comply with all applicable electrical
codes and be properly grounded (earthed).
Locate the electrical supply as shown in the illustrations
on the following pages. A separate circuit servicing only
this appliance is required. A ground fault circuit interrupter
(GFCI) is not recommended and may cause interruption of
operation.
ELECTRICAL REQUIREMENTS
34 kg
Electrical Supply
Service
0 mm
Receptacle
0 mm
Power Cord
18 mm
220–240 V AC, 50/60 Hz
320 W
grounding-type (earthed)