E Series Ovens
Planning Information
The E series oven can be installed in a standard or flush
inset application. If a cooktop is installed above an oven, a
minimum of 6 mm is required between the units. The loca-
tion of the electrical supply within the oven opening may
require additional cabinet depth.
Finish the edges of the opening. They may be visible when
the door is open.
For standard installations, the face trim overlaps stiles and
rails. Refer to the chart below.
For flush inset installations, a minimum 3 mm reveal is
required on all sides. To ensure consistent reveals, each
corner of the opening must be exactly 90°.
INSTALLATION REQUIREMENTS
BASE SUPPORT
60 cm Oven
76 cm Oven
TRIM OVERLAP
Top
Bottom
Sides
MIN
68 kg
115 kg
60 cm OVEN
76 cm OVEN
6 mm
25 mm
0 mm
0 mm
17 mm
18 mm
ELECTRICAL REQUIREMENTS—60 cm OVEN
Installation must comply with all applicable electrical
codes and be properly grounded (earthed).
For ease of installation, the electrical supply for the oven
should be placed in an adjacent cabinet within reach of the
conduit. Performance may be compromised if the electri-
cal supply is less than 230 volts.
The oven is supplied with a conduit consisting of two hot
lead conductors and a ground conductor. The wiring dia-
gram covering the control circuit is provided with the oven.
ELECTRICAL REQUIREMENTS—60 cm OVEN
Electrical Supply
Service
Conduit
Total Amps
Max Connected Load
ELECTRICAL REQUIREMENTS—76 cm OVEN
Installation must comply with all applicable electrical
codes and be properly grounded (earthed).
Locate the electrical supply flush with the back wall and
within the shaded area shown in the illustrations on the
following pages. For ease of installation, the electrical
supply for the oven can be placed in an adjacent cabinet
within reach of the conduit. Performance may be compro-
mised if the electrical supply is less than 240 volts.
The oven is supplied with a single phase and 3-phase con-
vertible power inlet box. The wiring diagram covering the
control circuit is provided with the oven.
ELECTRICAL REQUIREMENTS—76 cm OVEN
ELECTRICAL SUPPLY
Single Phase
3-Phase
Maximum Connected Load
Total Amps
Maximum Amps per Line
grounded, 230 VAC, 50 Hz
20 amp dedicated circuit
1.2 m
16
4.2 kW
220–240 V AC, 50/60 Hz
380–415 V AC, 50 Hz
4.8 kW
20
15
subzero.com | 19