Planning Information
ELECTRICAL REQUIREMENTS
Installation must comply with all applicable electrical
codes and be properly grounded (earthed).
Locate the electrical supply flush with the back wall and
within the shaded area shown in the illustration for your
specific installation on the following pages. For ease of
installation, the electrical supply for the oven can be
placed in an adjacent cabinet within reach of the conduit.
Performance may be compromised if the electrical supply
is less than 220 volts.
The oven is supplied with a single phase and 3-phase
convertible power inlet box. The wiring diagram covering
the control circuit is provided with the oven.
ELECTRICAL REQUIREMENTS—SINGLE OVEN
ELECTRICAL SUPPLY
Single Phase
3-Phase
MAX CONNECTED LOAD
Single Phase
3-Phase
ELECTRICAL REQUIREMENTS—DOUBLE OVEN
ELECTRICAL SUPPLY
Single Phase
3-Phase
MAX CONNECTED LOAD
Single Phase
3-Phase
220–240 V AC, 50/60 Hz
380–415 V AC, 50 Hz
4.2–4.8 kW
3.0–3.6 kW
220–240 V AC, 50/60 Hz
380–415 V AC, 50 Hz
8.4–9.6 kW
4.2–4.8 kW