Wolf M Series Design Manual page 48

Hide thumbs Also See for M Series:
Table of Contents

Advertisement

Gas Cooktops
Planning Information
A minimum 51 mm is required from the bottom of the
cooktop to combustible materials. If a cooktop is installed
above an oven, a minimum of 6 mm is required between
the units.
ELECTRICAL REQUIREMENTS
Installation must comply with all applicable electrical
codes and be properly grounded (earthed).
Locate the electrical supply as shown in the illustration
on the following pages. A separate circuit servicing only
this appliance is required. A ground fault circuit interrupter
(GFCI) is not recommended and may cause interruption of
operation.
ELECTRICAL REQUIREMENTS
Electrical Supply
Service
Receptacle
Power Cord
48 | English
220-240 V AC, 50/60 Hz
0.2 A
grounding-type (earthed)
1.8 m
GAS SUPPLY
Installation must conform with all applicable gas codes.
A gas supply line of 19 mm rigid pipe must be provided
to the cooktop. If local codes permit, a certified, .9 m long,
13 mm or 19 mm ID flexible metal appliance connector is
recommended to connect the units 1/2" NPT (or ISO 7/1-14)
male inlet to the gas supply line.
Gas Cooktops contain a regulator for natural gas and
LP gas.
Wolf natural gas cooktops will function up to 3124 m in
altitude without adjustment and LP gas cooktops will
function up to 2621 m. If the installation exceeds these
elevations, contact an authorized Wolf dealer for a high
altitude conversion kit.
GAS REQUIREMENTS
NATURAL GAS
Supply Pressure
LP GAS
Supply Pressure
WC
12.5 mbar
WC
25 mbar