Figure 3.181 Service > Event Handling > Configuration > Modbus Notifying Events Profile List - Advantech EKI-6333AC-4GP User Manual

Idustrial ieee 802.11 a/b/g/n/ac wi-fi ap with poe
Table of Contents

Advertisement

Setup the Modbus Notifying Events Profile. It supports up to a maximum of 10
profiles.
Figure 3.181 Service > Event Handling > Configuration > Modbus Notifying
When Add button is applied, the Modbus Notifying Events Profile Configuration
screen appears.
Figure 3.182 Service > Event Handling > Configuration > Modbus Notifying
The following table describes the items in the previous figure.
Item
Modbus Name
Description
Read Function
Modbus Mode
IP
Port
Device ID
Register
Logic Comparator
Value
Enable
Save
EKI-6333AC-4GP User Manual
Events Profile List
Events Profile Configuration
Description
Specify the Modbus profile name.
Value Range: 1 ~ 32 characters.
Specify a brief description for the profile.
Specify the read function for Notifying Events.
Specify the Modbus mode. It could be Serial or TCP.
Specify the IP for TCP on Modbus mode. IPv4 format.
Specify the port for TCP on Modbus mode.
Value Range: 1 ~ 65535.
Specify the device ID of the Modbus device.
Value Range: 1 ~ 247.
Specify the register number of the Modbus device.
Value Range: 0 ~ 65535.
Specify the logic comparator for Notifying Events. It could be '>',
'<', '=', '>=', or '<='.
Specify the value.
Value Range: 0 ~ 65535.
Click Enable checkbox to activate this profile setting.
Click Save to save the settings.