Figure 3.114 Field Communication > Bus & Protocol > Virtual Com; Figure 3.115 Field Communication > Bus & Protocol > Virtual Com - Advantech EKI-6333AC-4GP User Manual

Idustrial ieee 802.11 a/b/g/n/ac wi-fi ap with poe
Table of Contents

Advertisement

Item
Definition Enable
Save
Undo
Configure the gateway as the TCP (Transmission Control Protocol) Server. The TCP
Server waits for connections to be initiated by a remote TCP client device to receive
serial data. The setting allows user to specify specific TCP clients or allow any to
send serial data for serial data transmission bandwidth control and access control.
The TCP Server supports up to 128 simultaneous connections to receive serial data
from multiple TCP clients.
Figure 3.114 Field Communication > Bus & Protocol > Virtual COM
When Edit button is applied, a screen similar to this appears.
Figure 3.115 Field Communication > Bus & Protocol > Virtual COM
The following table describes the items in the previous figure.
Item
Serial Port
Operation Mode
Listen Port
Trust Type
Max Connection
Connection Idle Timeout Enter the idle timeout in minutes. The idle timeout is used to
Alive Check Timeout
Enable
Save
Undo
EKI-6333AC-4GP User Manual
Description
Check Enable checkbox to enable the TCP server configuration.
Click Save to save the settings.
Click Undo to cancel the settings.
Description
It displays the serial port ID of the serial port. The number of serial
ports varies from the purchased model.
Select TCP Server mode.
Indicate the listening port of TCP connection.
Value Range: 1 ~ 65535.
Select Allow All to allow any TCP clients to connect. Otherwise
select Specific IPs to limit certain TCP clients.
Set the maximum number of concurrent TCP connections. Up to
128 simultaneous TCP connections can be established.
Value Range: 1 ~ 128.
disconnect the TCP connection when idle time elapsed. Idle
timeout is only available when On-Demand is selected in the
Connection Control field.
Value Range: 0 ~ 3600 seconds.
Enter the time period of alive check timeout. The TCP connection
will be terminated if it doesn't receive response of alive-check
longer than this timeout setting. Alive check timeout is only
available when On-Demand is selected in the Connection
Control field.
Value Range: 0 ~ 3600 seconds.
Check Enable checkbox to activate the corresponding serial port
in specified operation mode.
Click Save to save the settings.
Click Undo to cancel the settings.