Figure 3.183 Service > Event Handling > Configuration > Modbus Managing Events - Advantech EKI-6333AC-4GP User Manual

Idustrial ieee 802.11 a/b/g/n/ac wi-fi ap with poe
Table of Contents

Advertisement

Setup the Modbus Managing Events Profile. It supports up to a maximum of 10
profiles.
Figure 3.183 Service > Event Handling > Configuration > Modbus Managing
When Add button is applied, the Modbus Managing Events Profile Configuration
screen appears.
Figure 3.184 Service > Event Handling > Configuration > Modbus Managing
The following table describes the items in the previous figure.
Item
Modbus Name
Description
Write Function
Modbus Mode
IP
Port
Device ID
Register
Value
Enable
Save
Events Profile List
Events Profile Configuration
Description
Specify the Modbus profile name.
Value Range: 1 ~ 32 characters.
Specify a brief description for the profile.
Specify the write function for Managing Events.
Specify the Modbus mode. It could be Serial or TCP.
Specify the IP for TCP on Modbus mode. IPv4 format.
Specify the port for TCP on Modbus mode.
Value Range: 1 ~ 65535.
Specify the device ID of the Modbus device.
Value Range: 1 ~ 247.
Specify the register number of the Modbus device.
Value Range: 0 ~ 65535.
Specify the value.
Value Range: 0 ~ 65535.
Click Enable checkbox to activate this profile setting.
Click Save to save the settings.