Optional Excel Power; Simultaneous Weld And Power - Miller Trailblazer 325 Diesel Owner's Manual

Diesel engine driven welder
Hide thumbs Also See for Trailblazer 325 Diesel:
Table of Contents

Advertisement

7-3. Optional Excel Power

7-4. Simultaneous Weld And Power

Weld Current in Amperes
250
180
125
90
0
.
Complete Parts List available at www.MillerWelds.com
60Hz
t
Excel  power
Run Tools at Idle Speed
Total Power in Watts
2200
3500
5200
8000
12,000 (Peak)
1
ALL
Speeds
120 V Full kVA Receptacle
Amperes
18
29
43
66
88
Excel power option provides gener-
ator power at idle speed and while
welding. This allows most job site
tools to operate properly at engine
idle speed.
!
Use GFCI protection when
operating auxiliary equip-
ment. If unit does not have
GFCI receptacles, use GFCI-
protected extension cord. Do
not use GFCI receptacles to
power life support equip-
ment.
1
120 V 20 A AC Excel Power
Receptacle
This receptacle supplies 2.4 kVA/
kW of pure 120 V, 60 Hz sine wave
power at ALL engine speeds.
Circuit protection is provided by
CB3 only; CB1 does not provide
protection to Excel power.
Combined output of all receptacles
limited to peak rating of the genera-
tor.
Ref. 248 009 / 250 717-C
240 V Full kVA Receptacle
Amperes
9
14
21
33
44
OM-258900 Page 39