8-5

Other Functions

Whether or not the operation indicator turns on can be set from the application.
Set it from the "LED" item on the "Input and output" screen.
To minimize the influence of frost and snow, the sensor unit has a built-in
heater. The heater is automatically activated when the external
temperature drops to 5°C (41°F) or lower.
(The heater is automatically deactivated when the
external temperature reaches 5°C (41°F) or higher.)
Whether or not the heater is active can be set from the application.
Set it from the "Heater" item on the "Input and output" screen.
If a large metal object (e.g. a shutter) is in front of the sensor, the microwave performance may
be affected, and the sensor operation may become unstable. In such a case, the operation
indicator blinks in green during sensor standby to notify of an unsuitable environment.
When the operation indicator blinks in green, check for a large metal object in front of the
sensor, and, if possible, install the sensor in a position free of such metal objects.
* Even if the operation indicator blinks green, it does not necessarily signify that the sensor is
operating in an unstable way.
All of the settings, including passwords and calibration values, can
be reset to their factory defaults. If the sensor is relocated, reset it.
Hold the Reset button for 5 seconds or longer to reset to the
factory settings. When the reset process is completed, the
operation indicator turns solid yellow for 2 seconds.
On the application, a reset can be
performed from the menu item
"Reset to factory settings."
Reference
During the assessment, snow accretion was not
Heater
position
Long press
(5 seconds or longer)