Mitsubishi Heavy Industries SRK100VNXWZRF Service Manual page 36

Inverter packaged air-conditioners
Table of Contents

Advertisement

(iv) Inspection procedures corresponding to detail of trouble
Sensor error
Sensor temperature characteristics (Room air
temperature, indoor heat exchanger temperature)
30
25
20
15
10
5
-
- 10
0
10
Indoor fan motor error
unit
unit
Power source reset
Is it normalized?
Malfunction by temporary noise
20
30
40
50
60
70
Temperature (˚C)
unit
Replace fan motor. (If the
error persists after replacing
the fan motor, replace the
indoor unit PCB.)
.
procedure.
35
-
-
'09•SRK-DB-087D
'22 • PAC-SM-422
Broken sensor wire,
connector poor connection
Defective fan motor, connector poor
connection, defective indoor unit PCB
.
37 for the fan motor and indoor unit PCB check
unit