'10 • SRK-T-099 '14•SRK-T-153 CONTENTS 1.1 SPECIFICATIONS ..................1.2 EXTERIOR DIMENSIONS ................ (1) Indoor units ..................(2) Outdoor units ..................(3) Wireless remote control ..............1.3 ELECTRICAL WIRING ................12 (1) Indoor units ..................12 (2) Outdoor units ..................14 1.4 PIPING SYSTEM ..................
Page 5
'10 • SRK-T-099 '14•SRK-T-153 (7) Phenomenon observed after shortcircuit, wire breakage on sensor ..36 .......... 36 (8) Checking the indoor electrical equipment (9) How to make sure of wireless remote control ........37 ■How to read the model name Example: SRK 10 C Series code Cooling only type...
'14•SRK-T-153 1.1 SPECIFICATIONS SRK10CNV Model Item Indoor unit SRK10CNV Outdoor unit SRC10CNV Cooling capacity (1) 2800 Power supply 1 Phase, 220 V, 50Hz Power Cooling 0.77 consumption Running Cooling current Operation data (1) Inrush current Cooling 3.64 Noise Cooling Sound level...
Page 7
'14•SRK-T-153 SRK13CNV Model Item Indoor unit SRK13CNV Outdoor unit SRC13CNV Cooling capacity (1) 3600 Power supply 1 Phase, 220 V, 50Hz Power Cooling 1.00 consumption Running Cooling current Operation data (1) Inrush current Cooling 3.60 Noise Cooling Sound level dB(A) level Exterior dimensions (Height x Width x Depth) 268 x 790 x 213...
Page 8
'14•SRK-T-153 SRK10CNS(-2) Model Item Indoor unit SRK10CNS(-2) Outdoor unit SRC10CNS(-2) Cooling capacity (1) 2800 Power supply 1 Phase, 220 V, 50Hz Power Cooling 0.77 consumption Running Cooling current Operation data (1) Inrush current Cooling 3.64 Noise Cooling Sound level dB(A) level Exterior dimensions (Height x Width x Depth) 268 x 790 x 213...
Page 9
'14•SRK-T-153 SRK13CNS(-2) Model Item Indoor unit SRK13CNS(-2) Outdoor unit SRC13CNS(-2) Cooling capacity (1) 3600 Power supply 1 Phase, 220 V, 50Hz Power Cooling 1.00 consumption Running Cooling current Operation data (1) Inrush current Cooling 3.60 Noise Cooling Sound level dB(A) level Exterior dimensions (Height x Width x Depth) 268 x 790 x 213...
'14•SRK-T-153 (3) Wireless remote control Models SRK10CNV, 13CNV Unit: mm Unit: mm 17.3 17.3 Models SRK10CNS, 13CNS SRK10CNS-2, 13CNS-2 Unit: mm Unit: mm 17.3 17.3...
Power source 220/230/240V 50Hz OUTDOOR UNIT CONTROL BOX 52C-4 52C-3 t° 1~ 250V 3.15A t° Wireless R-Amp Display IC15 Back up Sw Printed circuit board Meaning of Marks Color symbol Symbol Parts name Symbol Parts name Black Capacitor for Room temp. thermistor Blue White Fuse...
Page 14
Power source 220/230/240V 50Hz OUTDOOR UNIT CONTROL BOX 52C-4 52C-3 t° 1~ 250V 3.15A t° Wireless R-Amp Display IC15 Back up Sw Printed circuit board Meaning of Marks Color symbol Symbol Parts name Symbol Parts name Black Capacitor for Louver motor(RIGHT) Blue White Fuse...
Page 15
WHITE BLACK ORANGE BLACK BLACK INDOOR UNIT WHITE Power source 220-240V 50Hz WHITE BLACK BLACK WHITE Meaning of Marks ORANGE Symbol Parts name Capacitor for CM Capacitor for FMo CAPACITOR Compressor motor Fan motor Motor protector for CM Terminal block Connector...
'14•SRK-T-153 1.5 RANGE OF USAGE & LIMITATIONS Models All models Item Indoor return air temperature ( Upper, lower limits ) Refer to the selection chart Outdoor air temperature ( Upper, lower limits ) Refrigerant line ( one way ) length Max.
Page 18
'14•SRK-T-153 (2) Correction of cooling capacity in relation to one way length of refrigerant piping Piping length [m] Cooling 0.99 0.975 How to obtain the cooling capacity SRK13CNV 3510 3600 SRK13CNV...
'14•SRK-T-153 1.6 APPLICATION DATA Safety precautions • Please read these “Safety Precautions” first then accurately execute the installation work. • Though the precautionary points indicated herein are divided under two headings, WARNING and CAUTION , those points which are WARNING section. However, related to the strong possibility of an installation done in error resulting in death or serious injury are listed in the there is also a possibility of serious consequences in relationship to the points listed in the CAUTION section as well.
Page 20
'14•SRK-T-153 Standard accessories Necessary tools for the installation work (Installation kit) Q’ty Accessories for indoor unit Plus headed driver (Phillips screwdriver) Installation board ① Knife (Attached to the rear of the indoor unit) ② Wireless remote control Tape measure ③ Remote control holder Hammer Tapping screws...
'14•SRK-T-153 Limitations for one way piping length and vertical height difference One way piping length ( ) 15 m Outdoor unit is lower Vertical height Outdoor unit difference (h) is higher Installation of indoor unit Installation of installation board INSTALLATION SPACE (INDOOR UNIT) (FRONT VIEW) Look for the inside wall structures (Intersediate support or pillar and firaly install the unit after level surface has been...
Page 22
'14•SRK-T-153 Preparation of indoor unit ① Mounting of connecting wires ⓐ Remove the lid. ⓑ Remove the wiring clamp. ⓒ Connect the connecting wire securely to the terminal block. Use cable for interconnection wiring to avoid loosening of the wires. CENELEC code for cables Required field cables.
Page 23
'14•SRK-T-153 ⑤ Securing the indoor unit to the installation board Indoor unit Installing steps Installation board Latch (2 locations) 1.Hook the upper part of the indoor unit to the installation board. Wall Installation board 2.The unit can be installed simply by gently push- Indoor unit base lower latch ing in the lower part.
Page 24
'14•SRK-T-153 Installation of outdoor unit ① Make sure that the unit is stable in installation. Fix the unit to stable base. ② Perfrom wiring, making wire terminal numbers conform to Terminal block terminal numbers of indoor unit terminal block. Brown For power supply, indoor outdoor Interconnecting wire Blue...
Page 25
'14•SRK-T-153 ♦ Additional refrigerant charge When refrigerant piping exceeds 7.5m conduct additional refrigerant charge after refrigerant sweeping. 7.5m over 15m:Additional charge amount per meter = 10g/m [Example] How much amount of additional charge for 15m piping? (15 – 7.5)m × 10g/m=75g 75g for additional charge Insulation of connecting portion ①...
'14•SRK-T-153 1.7 OUTLINE OF OPERATION CONTROL BY MICROCOMPUTER (1) Operation control function by remote control Models SRK10CNV, 13CNV Remote control ◆ Operation section FAN SPEED button OPERATION MODE select button Each time the button is pushed, the Each time the button pushed, the indicator is switched over in turn.
'14•SRK-T-153 Models SRK10CNS, 13CNS Operation and indication section for remote control SRK10CNS-2, 13CNS-2 SRK10YJV-S Remote control SRK13YJV-S ◆ Operation section Operation section FAN SPEED button OPERATION MODE select button Each time the button is pushed, the Each time the button pushed, the indicator is switched over in turn.
Unit indication section SRK10YJV-S RUN light (green) SRK13YJV-S Illuminates during operation '14•SRK-T-153 and CLEAN operation. TIMER light (yellow) Illuminates during TIMER operation. (2) Unit ON/OFF button When the remote control batteries become weak, or if the remote control is lost or malfunctioning, this button may be used to turn the unit on and off.
'14•SRK-T-153 (5) Flap and louver control (Louver control function only CNS and CNS-2 models) (a) Flap (Flap stopped) (Swing) Angle of Flap from Horizontal Remote control display Approx. 10° Approx. 20° Approx. 30° Approx. 45° Approx. 60° COOL , DRY, FAN (b) Louver (Louver stopped) (Swing)
'14•SRK-T-153 1.4.6 3D auto operation (only SRK10CJV-2, 13CJV-2) (6) 3D auto operation (only CNS and CNS-2 models) Control the flap and louver by 3D AUTO button on the wireless remote control. Fan speed and air flow direction are automatically controlled, allowing the entire room to efficiently conditioned. (a) Detail of operation (i) Perform STEP1 →...
'14•SRK-T-153 (7) Timer operation (a) Comfortable timer setting (ON timer) (b) Sleep timer operation (c) OFF timer operation (8) Installation location setting (only CNS and CNS-2 models) (a) Setting (i) If the air conditioning unit is running, press the ON/OFF button to stop. (ii) Press the AIR FLOW (UP/DOWN) button and the AIR FLOW...
'14•SRK-T-153 (9) Outline of cooling operation (a) Operation of major functional components in Cooling mode Cooling Thermostat ON Thermostat OFF Failure Compressor Indoor fan motor Outdoor fan motor (b) Fan speed switching Model All model Fan speed Auto Auto fan control Speed 5 Speed 3 Speed 2...
'14•SRK-T-153 (11) Protective control function (a) Frost prevention for indoor heat exchanger (During cooling or dehumidifying) (i) Operating conditions Indoor heat exchanger temperature (Th2) is lower than 2.5ºC. 3 minutes elapsed after the start of operation. (ii) Detail of frost prevention operation Compressor Indoor fan Protects the fan tap just before frost prevention control.
'14•SRK-T-153 1.8 MAINTENANCE DATA (1) Cautions (a) If you are disassembling and checking an air conditioner, be sure to turn off the power before beginning. When work- ing on indoor units, let the unit sit for about minute after turning off the power before you begin work. When work- ing on an outdoor unit, there may be an electrical charge applied to the main circuit (electrolytic condenser), so begin work only after discharging this electrical charge (to DC 0 V or lower).
'14•SRK-T-153 (4) Troubleshooting procedure (If the air conditioner runs) Confirm the contents of the customer complaint. The cause of the trouble can be specifically identified. Eliminate the cause of the trouble and perform an Check the self-diagnosis display. operation check. See below.
'14•SRK-T-153 (6) Inspection procedures corresponding to detail of trouble Sensor error [Broken sensor wire, connector poor connection] Is connector connection good? Correct connection. Is sensor resistance value good? Replace sensor. Replace PCB. ◆ Sensor temperature characteristics (Room temp., indoor heat exchanger temp.) (Broken wire) (Short circuit) - 10...
Page 37
'14•SRK-T-153 Trouble of outdoor unit [Compressor malfunction of insufficient gas (refrigerant)] Replace capacitor for compressor. Is capacitor for compressor normal? Does compressor operation? Is connector for compressor connection Correct connection good? Replace compressor. Is heat exchanger sensor resistance Replace heat exchanger sensor value good? Check if there are any places where Does trouble persist after charging gas?
Page 38
'14•SRK-T-153 (9) How to make sure of wireless remote control Is remote Remote control control normal? defects Replace the display of indoor unit. Again pushing operating switch Is the unit Normal operable with remote control? Abnormality is not Operating the unit? found.
Page 39
'14•SRK-T-153 WALL MOUNTED TYPE RESIDENTIAL AIR-CONDITIONERS Split system, air cooled cooling only type 2. SRK19CNS, 25CNS...
Page 40
'10 • SRK-T-099 '14•SRK-T-153 CONTENTS 2.1 SPECIFICATIONS .................. 2.2 EXTERIOR DIMENSIONS ..............(1) Indoor units ..................(2) Outdoor units ..................(3) Wireless remote control ..............2.3 ELECTRICAL WIRING ................(1) Indoor units ..................(2) Outdoor units ..................2.4 PIPING SYSTEM ..................
'10 • SRK-T-099 '14•SRK-T-153 (7) Phenomenon observed after shortcircuit, wire breakage on sensor ..75 .......... 76 (8) Checking the indoor electrical equipment (9) How to make sure of wireless remote control ........77 ■How to read the model name Example: SRK 19 C Series code Cooling only type...
'14•SRK-T-153 2.1 SPECIFICATIONS SRK19CNS Model Item Indoor unit SRK19CNS Outdoor unit SRC19CNS Cooling capacity (1) 5300 Power supply 1 Phase, 220V, 50Hz Power Cooling 1.495 consumption Running Cooling current Operation data (1) Inrush current Cooling 3.55 Sound level dB(A) Hi : 47 Me : 42 Lo : 39 Noise Cooling level...
'14•SRK-T-153 SRK25CNS Model Item Indoor unit SRK25CNS Outdoor unit SRC25CNS Cooling capacity (1) 7200 Power supply 1 Phase, 220V, 50Hz Power Cooling 2.12 consumption Running Cooling current Operation data (1) Inrush current Cooling 3.40 Sound level dB(A) Hi : 50 Me : 46 Lo : 43 Noise Cooling level...
1090 Symbol Content 43.5 Gas piping ø 15.88 (5/8") (Flare) Liquid piping ø 6.35 (1 / 4") (Flare) Hole on wall for right rear piping ( ø 65) Hole on wall for left rear piping ( ø 65) Drain hose VP16 Outlet for wiring Outlet for piping(on both side)...
'14•SRK-T-153 2.3 ELECTRICAL WIRING (1) Indoor units All models LOUVER DISPLAY MOTOR LEFT WIRELESS RECEIVER CNX1 BACK-UP SW LOUVER MOTOR PRINTED RIGHT CIRCUIT BOARD FLAP ROOM TEMP. MOTOR SENSOR CNX2 HEAT EXCHANGER SENSOR 1 HUMIDITY SENSOR INTERFACE KIT SC-BIKN VARISTOR WHITE BLACK FUSE...
'14•SRK-T-153 (2) Outdoor units Model SRC19CNS 52X1 52X4 52X3 FUSE 250V 3.15A Y/GN PRINTED CIRCUIT VARISTOR BOARD Y/GN COMPRESSOR MOTOR MARK COLOR MARK COLOR FAN MOTOR BLACK WHITE ELECTRIC EXPANSION VALVE(COIL) BLUE YELLOW HEAT EXCHANGER SENSOR ORANGE Y/GN YELLOW /GREEN OUTDOOR AIR TEMP.
'14•SRK-T-153 2.5 RANGE OF USAGE & LIMITATIONS Models All models Item Indoor return air temperature ( Upper, lower limits ) Refer to the selection chart Outdoor air temperature ( Upper, lower limits ) Refrigerant line ( one way ) length Max.
Page 52
'14•SRK-T-153 (2) Correction of cooling capacity in relation to one way length of refrigerant piping Piping length [m] Cooling 0.99 0.975 0.965 0.95 How to obtain the cooling capacity SRK19CNS 5300 5168 SRK19CNS...
'14•SRK-T-153 2.6 APPLICATION DATA Safety precautions When install the unit, be sure to check whether the selection of installation place, power supply specifications, usage limitation (piping length, height differences between indoor and outdoor units, power supply voltage and etc.) and installation spaces. We recommend you to read this “SAFETY PRECAUTIONS”...
Page 54
'14•SRK-T-153 CAUTION Use the circuit breaker with sufficient breaking capacity. Take care when carrying the unit by hand. If the breaker does not have sufficient breaking capacity, it can cause the unit If the unit weights more than 20kg, it must be carried by two or more per- malfunction and fire.
Page 55
'14•SRK-T-153 Standard accessories Necessary tools for the installation work (Installation kit) Q'ty Accessories for indoor unit Plus headed driver (Phillips screwdriver) Installation board Knife ① (Attached to the rear of the indoor unit) ② Wireless remote control Tape measure ③ Remote control holder Hammer Tapping screws...
Page 56
'14•SRK-T-153 Limitations for one way piping length and vertical height difference Limitations for one way piping length and vertical height difference Total one way piping length ( ) Total one way piping length ( ) Max. 25 m Max. 25 m Vertical height difference (h) Vertical height difference (h) Max.
Page 57
'14•SRK-T-153 Preparation of indoor unit ① Mounting of connecting wires ⓐ Open the air inlet panel. ⓑ Remove the lid. ⓒ Remove the wiring clamp. ⓓ Connect the connecting wire securely to the terminal block. Use cable for interconnection wiring to avoid loosening of the wires.
Page 58
'14•SRK-T-153 ⑤ Securing the indoor unit to the installation board Latch (2 locations) Installing steps Indoor unit 1.Hook the upper part of the indoor unit to the installation board. Installation board Installation board 2.The unit can be installed simply by gently push- Wall ing in the lower part.
Page 59
'14•SRK-T-153 Installation of outdoor unit ① Make sure that the unit is stable in installation. Fix the unit to stable base. ② When installing the unit at a higher place or where it could be toppled by strong winds, secure the unit firmly with founda- tion bolts, wire, etc.
Page 60
'14•SRK-T-153 Air purge Compound pressure gauge Operation valve ① Tighten all flare nuts in the pipings both Pressure gauge indoor and outside wall so as not to Operation valve Gauge manifold cause leak. (two-way valve) -0.1MPa (Designed specifically for R22) (-76cmHg) ②...
'14•SRK-T-153 Installation of wireless remote control Mounting method of battery Fixing to pillar or wall Uncover the wireless remote control, and mount the bat- Conventionally, operate the wireless remote control teries [R03(AAA, Micro) 2 pieces] in the body regu- by holding in your hand. larly.
'14•SRK-T-153 2.7 OUTLINE OF OPERATION CONTROL BY MICROCOMPUTER (1) Operation control function by remote control Remote control ◆ Operation section Unit display section TIMER HI POWER 3D AUTO ON/OFF RUN light (green) 3D AUTO light (green) Illuminates during 3D AUTO operation. Illuminates during operation.
'14•SRK-T-153 (7) Timer operation (a) Comfortable timer setting (ON timer) (b) Sleep timer operation (c) OFF timer operation (8) Installation location setting (a) Setting (i) If the air conditioning unit is running, press the ON/OFF button to stop. (ii) Press the AIR FLOW (UP/DOWN) button and the AIR FLOW (LEFT/RIGHT) button together for 5 seconds...
'14•SRK-T-153 (9) Outline of cooling operation (a) Operation of major functional components in Cooling mode Cooling Thermostat ON Thermostat OFF Failure Compressor Indoor fan motor Outdoor fan motor (few minutes ON) (few minutes ON) (b) Fan speed switching Model SRK19CNS SRK25CNS Fan speed Auto...
'14•SRK-T-153 (11) Protective control function (a) Frost prevention for indoor heat exchanger (During cooling or dehumidifying) (i) Operating conditions Indoor heat exchanger temperature (Th2) is lower than 2.5ºC. 3 minutes elapsed after the start of operation. (ii) Detail of frost prevention operation Compressor Indoor fan Protects the fan tap just before frost prevention control.
Page 69
'14•SRK-T-153 Compressor overheat protection If the discharge pipe temperature (sensed by Th6) exceeds the set temperature value, the compressor stops. If the temperature is 95ºC or lower after a 3-minute delay, it starts again, but if this function is reactivated again within 60 minutes, it results in an abnormal stop. (RUN light : ON, TIMER light : 5-time flash) Operation possible Abnormal stop...
'14•SRK-T-153 2.8 MAINTENANCE DATA (1) Cautions (a) If you are disassembling and checking an air conditioner, be sure to turn off the power before beginning. When work- ing on indoor units, let the unit sit for about minute after turning off the power before you begin work. When work- ing on an outdoor unit, there may be an electrical charge applied to the main circuit (electrolytic condenser), so begin work only after discharging this electrical charge (to DC 0 V or lower).
'09•SRK-DB-087D '14•SRK-T-153 (5) Self-diagnosis table Indoor unit display panel Description Cause Display (flashing) condition TIMER of trouble light light • Broken heat exchanger sensor When a heat exchanger sensor 1 wire disconnection is detected while 1-time operation is stopped. (If a temperature of –28ºC or lower is detected for Heat exchanger 1 wire, poor connector sensor 1 error...
'14•SRK-T-153 (6) Inspection procedures corresponding to detail of trouble Sensor error [Broken sensor wire, connector poor connection] Is connector connection good? Correct connection. Is sensor resistance value good? Replace sensor. Replace PCB. ◆ Sensor temperature characteristics ◆ Discharge pipe sensor temperature characteristics (Room temp., indoor heat exchanger temp., outdoor heat exchanger temp., outdoor air temp.)
Page 74
'09•SRK-DB-087D '14•SRK-T-153 Over heat of compressor Gas shortage, defective discharge pipe sensor main Error of signal transmission Wiring error including power cable, defective indoor/ outdoor PCB ② ③ indoor ② ③ indoor ① ② outdoor sub...
Page 75
'14•SRK-T-153 Trouble of outdoor unit Insufficient refrigerant amount, Faulty power transistor, Broken compressor wire Service valve close, Defective EEV, Defective outdoor PCB ◆ Does 52X1 relay operate properly? main ....
Page 76
'14•SRK-T-153 See pages 53. (7) Phenomenon observed after shortcircuit, wire breakage on sensor (a) Indoor unit Phenomenon Operation Sensor mode Shortcircuit Disconnected wire Room temperature Cooling sensor Heat exchanger Cooling sensor Humidity sensor Cooling ■ Humidity sensor operation Failure mode Control input circuit resding Air conditioning system operation ①...
Page 77
Heat exchanger Cooling sensor Ourdoor air Cooling '14•SRK-T-153 temperature sensor Discharge pipe All modes Compressor stop. sensor (8) Checking the indoor electrical equipment (a) Indoor PCB check procedure Is there voltage between terminal Inspect power source blocks ① and ② ? (AC 220V) for outdoor unit.
Page 78
Operation SW ON Measure in this section '14•SRK-T-153 (9) How to make sure of wireless remote control Replace the display of indoor unit. indoor unit The figare below shows the SRK series.
Page 149
RESIDENTIAL AIR-CONDITIONING TECHNICAL MANUAL & PARTS LIST Because of our policy of continuous improvement, we reserve the right to make changes in all specifications without notice. Copyright MITSUBISHI HEAVY INDUSTRIES, LTD.