Mitsubishi Heavy Industries SRK100VNXWZRF Service Manual page 202

Inverter packaged air-conditioners
Table of Contents

Advertisement

s
(d) Operation mode, Fan speed mode information tables
(i) Operation mode
Display pattern when
in service mode
RUN light
( 10's digit )
-
1-time flash
2-time flash
3-time flash
4-time flash
becomes as follows.
Mode
Operation mode
Fan speed mode
mode: COOL, Fan
ON
RUN light
(10's digit)
OFF
ON
TIMER light
(1's digit)
OFF
4-time flash
Operation mode
when there is an
abnormal stop
AUTO
DRY
COOL
FAN
HEAT
mode: HI
1.5 sec.
0.5 sec.
0.5 sec.
201
-
(ii) Fan speed mode
Display pattern when
in service mode
TIMER light
(1's digit)
-
2 -time flash
3 -time flash
4 -time flash
5 -time flash
6 -time flash
7 -time flash
operation mode and fan speed mode
11-second interval
-
'09•SRK-DB-087D
'22 • PAC-SM-422
2-time flash.
Fan speed
mode when
there is an
abnormal stop
AUTO
HI
MED
LO
ULO
HI POWER
ECONO

Advertisement

Table of Contents
loading

Table of Contents