NETGEAR AV Series User Manual page 82

Fully managed switches
Hide thumbs Also See for AV Series:
Table of Contents

Advertisement

The first time that you log in, no password is required. However, you then must
specify a local device password to use each subsequent time that you log in.
The Overview page displays.
4. In the Device Details section, below the OOB IP Address field, click the pencil icon.
The Edit OOB IP Address window displays.
5. From the OOB IP Settings menu, select DHCP Client.
WARNING:
If you are logged in to switch over the OOB port, when you click the
Apply button, you are disconnected and need to log in to the switch at the new IP
address that is assigned by the DHCP server. If you do not know the new IP address,
determine it by accessing the DHCP server or by using an IP scanner utility.
6. Click the Apply button.
Your settings are saved. The window closes. The Overview page displays again.
7. To save the settings to the running configuration, at the top of the page, click the
Save icon or text.
Set the STP network redundancy for the
switch
You can set the Spanning Tree Protocol (STP) network redundancy for the switch. This
is also referred to as the bridge priority, which is the priority for a multiple spanning
tree (MST) instance on the switch.
When switches or bridges are running STP, each is assigned a priority. After exchanging
bridge protocol data units (BPDUs), the switch with the lowest priority value becomes
the root bridge and the other devices become backup or redundant bridges. The bridge
priority is a multiple of 4096. The range is from 0 to 61440. The default is 32768.
The following table shows how the network redundancy settings in the AV UI align with
the bridge priority values in the main UI.