Installation - ADJ 32 HEX PANEL IP User Manual

Hide thumbs Also See for 32 HEX PANEL IP:
Table of Contents

Advertisement

I N S T A L L A T I O N
The 32 Hex Panel IP is fully operational in three different mounting positions: hanging upside-down,
mounted sideways on trussing, or set on a flat level surface. Be sure this fixture is kept at least 12m
(40ft) away from any flammable materials (decoration etc.). ALWAYS use and install and appropriately
rated safety cable as a safety measure to prevent accidental damage and/or injury in the event that
the clamp fails.
Screw one clamp into the Omega bracket with an M12 screw and nut. Insert the quick-lock fasteners
of the Omega bracket into the matching holes of the adjustable mounting bracket. Tighten the quick-
lock fasteners fully clockwise. Pull the safety-cable through the openings located on the rear of the
unit and over the trussing system or a safe fixation spot. Insert the end in the carabine and tighten the
safety screw.
Always ensure that the unit is firmly fixed to avoid vibration and slipping during operation. Always en-
sure that the structure to which you are attaching the unit is secure and is able to support at least 10
times the unit's weight. ALWAYS use safety cables that can hold 12 times the weight of the unit when
installing the fixture.
This equipment must be installed by a professional, and it must be installed out of the reach of the
general public.
Ensure ALL connections and end caps are properly sealed with a non-conductive dielectric
grease (available at most electrical supply stores) to prevent water ingress/condensation and/
or corrosion.
OPTIONAL CLAMP (Not Included)
1
ADJUSTABLE MOUNTING BRACKET
2
OPTIONAL OMEGA BRACKET (Not Included)
3
11