Pump Menu: Priming
PRIMING
DISABLED/ENABLED

Setting Priming Features

MAX PRIMING TIME
Note: Priming features are only accessible if priming
PRIMED SENSITIVITY
is "Enabled".
1. Press Menu.
PRIMING DELAY
2. Use Down arrow to scroll to "Priming" and press
DISABLED/ENABLED
Select.
3. The factory default is set to priming "Enabled". To
disable, press Select.
4. Press Save if you have changed the setting - this
will save the selection.
5. Press the Down arrow - the screen will read "Max
Priming Time".
6. To change from factory default, press Select. The
cursor will highlight.
7. Use the Up or Down arrows to change the time
from 1 minute to 30 minutes.
8. Press Save to save.
9. Press the Down arrow - the screen will read "Priming
Range". Default is "5".
10. Press Select to change the priming range. The
cursor will highlight the number.
11. Use the Up or Down arrows to change from 1 to
10. Increasing the number allows the drive to detect
prime with less water flow.
12. Press Save to save.
13. Press the Down arrow - the screen will read "Priming
Delay". Default is 20 seconds.
14. Press Select to change the priming delay time.
15. Use the Up or Down arrows to change from 1
second to 10 minutes.
CAUTION: Increasing the time causes the pump
to stay in the priming mode longer.
1. Disable priming on automation control system.
3. Disable priming on pump.
INTELLIFLO
Variable Speed Pump Installation and User's Guide
®
Default: Enabled
16. Press Save to save the setting.
(1 min. to 30 min. hrs.) Default: 11 minutes
17. Press Back to exit.
(1 - 100%) Default: 1
Disabling Priming with an Automation
(1 second - 10 minutes) Default: 20 seconds
System
Disabled / Enabled - Default: Enabled
When the IntelliFlo
to an automation control system, the priming feature
on the pump cannot be disabled by the external
automation control system only. It must also be
disabled on the pump itself.
If priming is enabled on start up, the pump responds to its
internal settings before responding to commands from an
automation control system.
If the pump is connected to an automation control system
and priming is not desired, disable the priming feature
on both the pump and the automation control system.
To disable priming with an automation system:
1. Disable the priming feature on the automation control
system at the load center or using a system remote.
(Refer to the automation control system user's guide
for additional information).
2. Temporarily disconnect the RS-485 communication
cable.
3. Open the lid to the control panel to disable priming
on the pump. Press Menu, use the Arrow buttons to
scroll and select "Priming", then select "Disabled" (the
factory default is set to "Enabled"). Press Back to exit
the menu.
4. Once priming is disabled, reinstall the RS-485
communication cable.
2. Disconnect the RS-485 communication cable.
4. Reinstall the RS-485 communication cable.
Variable Speed Pump is connected
®