5.3 Configuration and handling

5.3.1 Configuring advertising interval

Press the SW2 button on the C209 to change the advertising interval.
When SW2 is pressed, the advertising interval cycles through the available advertising intervals. For
best performance, it is advisable to use the fastest advertising interval. The LED will blink shortly to
indicate the advertising interval, with 1 blink indicating the fastest advertising.
Figure 25: C209 with cover and buttons
C209 tags are simply configured over the UART interface using AT commands.
The AT commands that can be used to configure the interface are described in
Command
AT+UMLA=1
AT+GMM
AT+TXPWR=<valid_tx_power>
AT+TXPWR?
Table 5: C209 AT commands
For
to take effect the software must be reset – either by pressing the reset button or power
+TXPWR
cycling the module. The configuration is persistently stored in flash.
All commands are echoed and responded with either
terminated with
\r.
The UART interface is available for 10 seconds after reset with the settings 115200 bps, with no
flow control.

5.3.2 Enabling/disabling advertising

Press and hold the SW2 button for ~3 seconds to enable/disable advertising. If the tag is advertising,
press and hold the button to stop it advertising. The onboard RGB LED blinks blue when advertising
is enabled. The blinking interval correlates to the advertising interval.
UBX-22006906 - R03
C1-Public
Description
Read Local MAC address
Read the model identifier, NINA-B4-TAG
<valid_tx_power> can be one of: -40, -30, -20, -16, -12, -8, -4, 0, 2, 3, 4, 5, 6, 7, 8 (dBm)
Query the set TX power
or
\r\nOK\r\n
\r\nERROR\r\n