10.1.2 Pump in constant-curve control mode
In constant-curve control mode, the pump
performance lies between the maximum and
minimum curve of the pump. See the figure below.
H
Max.
Min.
Pump in constant-curve control mode
Setting to maximum curve:
Press
continuously to change over to the
maximum curve of the pump. The top light field
flashes. When the top light field is on, press
3 seconds until the light field starts flashing.
To change back, press
desired setpoint is indicated.
Example
Pump set to maximum curve.
The figure below shows that the top light field is
flashing, indicating maximum curve.
H
Q
Maximum-curve duty
Setting to minimum curve:
Press
continuously to change over to the
minimum curve of the pump. The bottom light field
flashes. When the bottom light field is on, press
for 3 seconds until the light field starts flashing.
20
Q
for
continuously until the
To change back, press
desired setpoint is indicated.
Example
Pump set to minimum curve.
The figure below shows that the bottom light field is
flashing, indicating minimum curve.
H
Minimum-curve duty
10.1.3 Start-stop of pump
If you have stopped the pump by pressing
and the "Stop" text on the control panel
is on, you can only give it free to operation
by pressing
again.
If you have stopped the pump by pressing
, you can restart it by pressing
using Grundfos GO.
Start the pump by pressing
pressing
until the desired setpoint is indicated.
Stop the pump by pressing
stopped, the "Stop" text next to the button is on. You
can also stop the pump by continuously pressing
until none of the light fields are on.
You can also stop the pump with the Grundfos GO or
via a digital input set to External stop. See section
Priority of settings.
Related information
16. Priority of settings
10.1.4 Resetting of fault indications
Reset a fault indication in one of the following ways:
Via the digital input if it has been set to Alarm
resetting.
Briefly press
or
on the pump. This does not
change the setting of the pump. You cannot reset
a fault indication by pressing
have been locked.
Switch off the power supply until the indicator
lights are off.
Switch the external start-stop input off and on.
With Grundfos GO.
continuously until the
Q
or by
or by continuously
. When the pump is
or
if the buttons