Burkert 8718 Operating Instructions Manual page 26

Lfc, liquid flow controller lfm, liquid flow meter
Hide thumbs Also See for 8718:
Table of Contents

Advertisement

Available languages

Available languages

Outputs:
Actual value:
Binary output:
Display:
Light-emitting diodes: Status display for Power, Communication, Limit, Error (assignment can be
Field buses:
Electrical connections:
26
S tandard signal 0/4...20 mA
max. burden: 600 Ω
Resolution: 20 µA
Standard signal 0...5/10 V
max. current: 10 mA
Resolution: 10 mV
potential-free changers 60 V, 1 A, 60 VA (assignment can be configured)
8709 and 8719: 2 binary outputs
8708 and 8718: 1 binary output
configured)
8709 and 8719: 4 LEDs
8708 and 8718: 3 LEDs
alternative to the standard signal version
PROFIBUS DP V1
CANopen
8719 and 8709:
8-pole round socket
15-pole Sub-HD socket
optional: 5-pole M12 socket or plug for field bus
8718 and 8708:
15-pole Sub-D plug
optional: 5-pole M12 socket or plug for field bus