Automatic Rebuild - Promise Technology SuperTrak SX6000 Procedure

Hide thumbs Also See for SuperTrak SX6000:
Table of Contents

Advertisement

Automatic Rebuild

When automatic rebuilding begins, the disk drive in Channel 4 reappears, confirming
that it is the target of the rebuild. The UltraTrak controller will attempt to rebuild the data
on the failed drive. If it can, the Define Array Menu will display Rebuilding progress and
the target disk drive (above).In this example, the drive on Channel 4 is being rebuilt and
progress is currently at 25 percent. Allow the UltraTrak controller to rebuild the disk
drive.
If this action corrects the problem, return the array to service.
If the array goes
CRITICAL
shut down the computer (SuperTrak) or the UltraTrak and remove the drive for
testing, as described under Remove a Disk Drive for Testing, Testing a Disk Drive,
and Results and Action, above.
If Rebuilding does not start, the array status will remain critical. Recalling which channel
the failed drive was on, you can remove the drive for testing.
Offline Array Recovery Procedures—SuperTrak SX6000 and UltraTrak, Version 5a
again and the controller tries to rebuild the same disk drive,
13 of 34